 375W Quad Output with PFC Function
Features :
Universal AC input / Full range
QP-375
Built-in active PFC function, PF>0.95
series
Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH3,4 are isolated from other outputs and the polarity can be reversed No minimum load requirement for CH2,3,4 All output can be adjustable from -5~+10% With power good and fail signal output Built-in remote ON-OFF control Fixed switching frequency at 100KHz 3 years warranty
..
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER(max.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE QP-375-5A CH1 5V 30A 378W CH2 +12V 10A CH3 12V 6A 0 ~ 6A CH4 12V 3A 0 ~ 3A QP-375-5B CH1 +5V 30A 357W CH2 +12V 10A CH3 12V 6A 0 ~ 6A CH4 5V 3A 0 ~ 3A QP-375-5C CH1 5V 30A 378W 4.75 ~ 5.5V 11.4 ~ 13.2V 14.3 ~ 16.5V 14.3 ~ 16.5V 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% CH2 +12V 9A CH3 15V 4A 0 ~ 4A CH4 15V 4A 0 ~ 4A
3.5 ~ 40A 0 ~ 16A
3.5 ~ 40A 0 ~ 16A
3.5 ~ 40A 0 ~ 16A
RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 50mVp-p 100mVp-p 120mVp-p 120mVp-p 50mVp-p 100mVp-p 150mVp-p 150mVp-p 240mVp-p 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V 11.4 ~ 13.2V 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V -----1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8% 1.0% 0.5% 0.8%
800ms, 50ms at full load 36ms at full load
Note.7 85 ~ 264VAC
120 ~ 370VDC PF>0.98/115VAC at full load 77% 77%
47 ~ 63Hz PF>0.95/230VAC 77% 6A/115VAC 3A/230VAC COLD START 45A <2mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover
80 5 (TSW1) Detect on heatsink of Q1,Q2 power transistor) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms FUNCTION RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF REMOTE CONTROL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION
(Note 4)
-10 ~ +60 -20 ~ +85
(Refer to output load derating curve) , 10 ~ 95% RH
20 ~ 90% RH non-condensing 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 75.9K hrs min. MIL-HDBK-217F (25 ) 280*127*63.5mm (L*W*H) 2.4Kg; 6pcs/14.8Kg/1.45CUFT
HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Peak current can not exceed 60 sec. 6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs. 7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-375-SPEC 2007-04-11
375W Quad Output with PFC Function
Features :
Universal AC input / Full range
QP-375
Built-in active PFC function, PF>0.95
series
Protections:Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH3,4 are isolated from other outputs and the polarity can be reversed No minimum load requirement for CH2,3,4 All output can be adjustable from -5~+10% With power good and fail signal output Built-in remote ON-OFF control Fixed switching frequency at 100KHz 3 years warranty
..
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER(max.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE QP-375-5D CH1 +5V 30A 3.5 ~ 40A 378W 120mVp-p 11.4 ~ 13.2V 1.0% 0.5% 0.8% 120mVp-p 11.4 ~ 13.2V 1.0% 0.5% 0.8% 240mVp-p 22.8 ~ 26.4V 1.0% 0.5% 0.8% 4.75 ~ 5.5V 1.0% 0.5% 0.8% 36ms at full load
Note.7 85 ~ 264VAC
QP-375-5E CH2 +12V 9A 0 ~ 16A CH3 12V 4A 0 ~ 6A CH4 24V 3A 0 ~ 3A CH1 +5V 30A 3.5 ~ 40A 378W 100mVp-p 4.75 ~ 5.5V 1.0% 0.5% 0.8% 120mVp-p 11.4 ~ 13.2V 1.0% 0.5% 0.8% 120mVp-p 22.8 ~ 26.4V 1.0% 0.5% 0.8% 240mVp-p 22.8 ~ 26.4V 1.0% 0.5% 0.8% CH2 +12V 9A 0 ~ 16A CH3 24V 3A 0 ~ 4A CH4 24V 2A 0 ~ 3A
RIPPLE & NOISE (max.) Note.2 100mVp-p
800ms, 50ms at full load 120 ~ 370VDC PF>0.98/115VAC at full load 78%
47 ~ 63Hz PF>0.95/230VAC 78% 6A/115VAC 3A/230VAC COLD START 45A <2mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover
80 5 (TSW1): Detect on heatsink of Q1,Q2 power transistor) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms FUNCTION RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF REMOTE CONTROL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 5)
-10 ~ +60 -20 ~ +85
(Refer to output load derating curve) , 10 ~ 95% RH
20 ~ 90% RH non-condensing 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 75.9K hrs min. MIL-HDBK-217F (25 ) 280*127*63.5mm (L*W*H) 2.4Kg; 6pcs/14.8Kg/1.45CUFT
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Peak current can not exceed 60 sec. 6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs. 7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-375-SPEC 2007-04-11
375W Quad Output with PFC Function
Mechanical Specification
92 250
LED 8.2
QP-375
Case No. 927A
42.4 31.7 5 7 165.1 165.1 240
series
Unit:mm
63.5 37
Air flow direction
13.9 10.1
280
O/P TB2
TB1 I/P 1 2 3 165.1 2-M4 L=6 8.2
+V2 ADJ. +V3 ADJ. +V4 ADJ.
9.5
1 2 3 4 5 6 7 8 9 10
8-M4 L=6 6-M3 L=6 99.1 99.1 113
+V1 ADJ.
CN62
16 127
42.5 30.4
9.5
CN62 Pin No. Assignment : JST S6B-XH or equivalent AC Input Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG
DC Output Terminal Pin No. Assignment
Pin No. 1,2 3,4,5 6 7 Assignment +V1 COM(V1 and V2) +V2 +V3 Pin No. 8 9 10 Assignment -V3 +V4 -V4
Pin No. Assignment Mating Housing Terminal 1 PF(Power good / Fail signal) GND 2 RS3 JST XHP JST SXH-001T-P0.6 RS+ or equivalent or equivalent 4 RC5 RC+ 6
Block Diagram
POWER SWITCHING PWM CONTROL FAN RECTIFIERS & FILTER MA & CONTROL I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & P.F.C. POWER SWITCHING RECTIFIERS & FILTER MA & CONTROL PF O.L.P. O.T.P. PWM CONTROL O.V.P. DETECTION CIRCUIT REGULATOR RECTIFIERS & FILTER
fosc : 100KHz
+V4 -V4 +V3 -V3 +S +V1 COM -S +V2 PF
RECTIFIERS & FILTER
FG
+RC -RC
Derating Curve
Output Derating VS Input Voltage
100
100 90
80
80 70
60
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 (HORIZONTAL)
40
60 50 40
20
-10
85
95
105
115
125
135
180
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-375-SPEC 2007-04-11
375W Quad Output with PFC Function
Features :
QP-375-24
Universal AC input / Full range Built-in active PFC function, PF>0.95
series
Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH3,4 are isolated from other outputs and the polarity can be reversed No minimum load requirement for CH2,3,4 All output can be adjustable from -5~+10% With power good and fail signal output Built-in remote ON-OFF control Fixed switching frequency at 100KHz 3 years warranty
..
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER(max.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE QP-375-24B CH1 +24V 10A 1 ~ 10A 386W 50mVp-p 4.5 ~ 5.5V 1.0% 0.5% 0.8% 120mVp-p 10.8 ~ 13.2V 1.0% 0.5% 0.8% 120mVp-p 10.8 ~ 13.2V 1.0% 0.5% 0.8% 21.6 ~ 26.4V 1.0% 0.5% 0.8% 36ms at full load
Note.7 85 ~ 264VAC
QP-375-24C CH2 +5V 10A 0 ~ 16A CH3 12V 4A 0 ~ 4A CH4 12V 4A 0 ~ 4A CH1 +24V 10A 1 ~ 10A 410W 240mVp-p 21.6 ~ 26.4V 1.0% 0.5% 0.8% 50mVp-p 4.5 ~ 5.5V 1.0% 0.5% 0.8% 150mVp-p 13.5 ~ 16.5V 1.0% 0.5% 0.8% 150mVp-p 13.5 ~ 16.5V 1.0% 0.5% 0.8% CH2 +5V 10A 0 ~ 10A CH3 15V 4A 0 ~ 4A CH4 15V 4A 0 ~ 4A
RIPPLE & NOISE (max.) Note.2 240mVp-p
800ms, 50ms at full load 120 ~ 370VDC PF>0.98/115VAC at full load 80%
47 ~ 63Hz PF>0.95/230VAC 78% 6A/115VAC 3A/230VAC COLD START 45A <2mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after condition is removed CH1:27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover
80 5 (TSW1) Detect on heatsink of Q1,Q2 power transistor) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms FUNCTION RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF REMOTE CONTROL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION
(Note 4)
-10 ~ +60 -20 ~ +85
(Refer to output load derating curve) , 10 ~ 95% RH
20 ~ 90% RH non-condensing 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 75.9K hrs min. MIL-HDBK-217F (25 ) 280*127*63.5mm (L*W*H) 2.4Kg; 6pcs/14.8Kg/1.45CUFT
HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Peak current can not exceed 60 sec. 6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs. 7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-375-24-SPEC 2007-04-11
375W Quad Output with PFC Function
Mechanical Specification
QP-375-24
92
series
Case No. 927A
165.1 165.1 240
Unit:mm
250
LED 8.2
63.5 37
13.9 10.1
280
42.4 31.7 5 7
Air flow direction
O/P TB2
TB1 I/P 1 2 3 165.1 2-M4 L=6 8.2
+V2 ADJ. +V3 ADJ. +V4 ADJ.
9.5
1 2 3 4 5 6 7 8 9 10
8-M4 L=6 6-M3 L=6 99.1 99.1 113
+V1 ADJ.
CN62
16 127
42.5 30.4
9.5
CN62 Pin No. Assignment : JST S6B-XH or equivalent AC Input Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG
DC Output Terminal Pin No. Assignment
Pin No. 1,2 3,4,5 6 7 Assignment +V1 COM(V1 and V2) +V2 +V3 Pin No. 8 9 10 Assignment -V3 +V4 -V4
Pin No. Assignment Mating Housing Terminal 1 PF(Power good / Fail signal) GND 2 RS3 JST XHP JST SXH-001T-P0.6 RS+ or equivalent or equivalent 4 RC5 RC+ 6
Block Diagram
POWER SWITCHING PWM CONTROL FAN RECTIFIERS & FILTER MA & CONTROL I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & P.F.C. POWER SWITCHING RECTIFIERS & FILTER MA & CONTROL PF O.L.P. O.T.P. PWM CONTROL O.V.P. DETECTION CIRCUIT REGULATOR RECTIFIERS & FILTER
fosc : 100KHz
+V4 -V4 +V3 -V3 +S +V1 COM -S +V2 PF
RECTIFIERS & FILTER
FG
+RC -RC
Derating Curve
Output Derating VS Input Voltage
100
100 90
80
80 70
60
LOAD (%)
LOAD (%)
0 0 10 20 30 40 50 60 (HORIZONTAL)
40
60 50 40
20
-10 -10
85
95
105
115
125
135
180
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-375-24-SPEC 2007-04-11
375W Quad Output with PFC Function
Mechanical Specification
250 158 5 240
QP-375P
series
Unit:mm
5
35
LED 1 2 CN62 +V1 ADJ. 3 4 1 6
123
113
5 TB1 1 2 3 FS1 T6.3A/250V +V3 ADJ. +V4 ADJ. +V2 ADJ. 6 7 8 9 10
TB2
6-
3.2
52
CN62 Pin No. Assignment : JST S6B-XH or equivalent AC Input Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG
DC Output Terminal Pin No. Assignment
Pin No. 1,2 3,4,5 6 7 Assignment +V1 COM(V1 and V2) +V2 +V3 Pin No. 8 9 10 Assignment -V3 +V4 -V4
Assignment Terminal Pin No. Mating Housing PF(Power good / Fail signal) 1 GND 2 RS3 JST XHP JST SXH-001T-P0.6 RS+ or equivalent or equivalent 4 RC5 RC+ 6
Derating Curve
Output Derating VS Input Voltage
100
100
80CFM
80
90 80 70
60
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 (HORIZONTAL)
40
60 50 40
20
-10
85
95
105
115
125
135
180
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-375P-SPEC 2007-04-11
375W Quad Output with PFC Function
Control terminal instruction manual
QP-375
series
+V1 +V1
+ Load -
+V1 +V1 PF +5V GND
+ Load -
+V1 +V1 + Load COM COM COM
PF GND RSRS+ RCRC+
COM COM COM
COM COM COM DC 0~15V
PF GND RSRS+ RCRC+
+V2 +V3 -V3 +V4 -V4
PF GND RSRS+ RCRC+
+V2 +V3 -V3 +V4 -V4
+V2 +V3 -V3 +V4 -V4
Remote Sensing
Power Fail Signal
PF Signal is the voltage difference between "GND" and "PF" pin output
Power Fail Signal
Power ON: When V RC+ , RC- =0 ~ 0.8V or Open Power OFF: When V RC+ , RC- =4 ~ 10V
+V1 +V1 COM COM COM COM +V2 +V3 -V3 -V3 +V4 -V4 -V4 -V3+(-V4) COM
+V1 +V1 COM COM COM +V2 +V3 -V3 +V4 -V4
V3,V4 All Negative(-)
V3 Puls Negative(-)
+V1 +V1 COM COM COM COM +V2 +V3 +V3 -V3 +V4 +V4 -V4 +V3+V4 COM
+V1 +V1 COM COM COM +V2 +V3 -V3 +V4 -V4
V3,V4 All Positive(+)
V3 Plus V4 Positive(+)
File Name:QP-375-SPEC 2007-04-11


▲Up To Search▲   

 
Price & Availability of QP-375-24B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X